Your current position:
Homepage
/
/
/
Standard fast cooling oil bath
1/1
Number of views:
1073
GL-8310S

Standard fast cooling oil bath

The GL-8310S standard fast cooling oil bath produced by AIKOM company is specially designed for temperature measurement room verification and calibration. It adopts AIKOM company's unique jet mixing patented technology, with ultra-low vibration and silent design, equipped with a high-temperature fast cooling system and smoke exhaust. Equipped with RS-232 communication interface, it can form an automatic calibration system.
  • Product Description

    The GL-8310S standard fast cooling oil bath produced by AIKOM company is specially designed for temperature measurement room verification and calibration. It adopts AIKOM company's unique jet mixing patented technology, with ultra-low vibration and silent design, equipped with a high-temperature fast cooling system and smoke exhaust. Equipped with RS-232 communication interface, it can form an automatic calibration system.

  • Application areas

    Used as a temp. measurement standard constant temperature device, with a groove depth that meets the standard mercury thermometer as the calibration transmission standard. Equipped with upper computer verification software and data acquisition device to form an automatic verification system for temperature measurement room, completing the automatic verification and verification of thermal resistance thermometers, thermocouples, and integra-ted thermometers, as well as the transmission and comparison verification of temperature switches, pressure type thermometers (meters), mercury (alcohol) glass rod thermometers, etc.

  • Product characteristics

    Equipped with a built-in oil cooler for direct air cooling, it can achieve rapid cooling of the oil bath at high temperatures, dropping from 300℃ to 100℃ in just 30 minutes, greatly improving work efficiency.
    Equipped with a detachable smoke exhaust to exhaust the oil fumes generated during high temperatures to the outdoors.
    The working liquid level remains constant, and the adaptive medium expands at high temperatures without overflow, so there is no need to replenish oil during use.
    Adopting jet mixing technology and precise PID temperature control, it can achieve rate temperature control.
    Independent overtemperature protection system ensures safe and reliable machine operation.
    The instrument feet are designed with adjustable universal wheels, allowing one person to easily move the device.
    Small size, light weight, and low noise.

  • Specificatiom

    Display range:  0℃∼310℃
    Working temperature:  80℃∼300℃
    Working medium:  Silicone oil (50cst)
    Working area:  Diam 138mm
                            Depth 510mm
    Liquid volume:  About 15L
    Stirring mode:  Ejector mixing, 3 speeds
    Cooling mode:  Forced air cooling
    Heating modes:  By electric heater
    Temp. control mode:  Full digital PID control
    Display resolution:  0.001℃
    Stability:  0.01℃/10mins
    Display accuracy:  ±0.05℃ (After calibration)
    Horizontal temp. field:  0.01℃ (at 100℃)
    Vertical temp. field:  0.02℃ (at 100℃)
    Heating up time:  About 1hr (30℃∼300℃)
    Cooling time:  About 1hr (300℃∼60℃)
    Working voltage:  220V±10%, 50Hz
    Nominal power:  About 2900W
    Size:  About 405x350x870mm
    Weight:  About 35Kg

  • Product Warranty

    Warranty period of 12 months, free warranty or replacement in case of quality defects

  • After-sale service

    Free information exchange platform technical support, operational answers or video tips, paid maintenance services

  • Environmental impact

    Use green refrigerant, compliance with world environmental protection agreement.

  • optional accessories

    Options:

Product Description
Application areas
Product characteristics
Specificatiom
Product Warranty
After-sale service
Environmental impact
optional accessories

The GL-8310S standard fast cooling oil bath produced by AIKOM company is specially designed for temperature measurement room verification and calibration. It adopts AIKOM company's unique jet mixing patented technology, with ultra-low vibration and silent design, equipped with a high-temperature fast cooling system and smoke exhaust. Equipped with RS-232 communication interface, it can form an automatic calibration system.

Used as a temp. measurement standard constant temperature device, with a groove depth that meets the standard mercury thermometer as the calibration transmission standard. Equipped with upper computer verification software and data acquisition device to form an automatic verification system for temperature measurement room, completing the automatic verification and verification of thermal resistance thermometers, thermocouples, and integra-ted thermometers, as well as the transmission and comparison verification of temperature switches, pressure type thermometers (meters), mercury (alcohol) glass rod thermometers, etc.

Equipped with a built-in oil cooler for direct air cooling, it can achieve rapid cooling of the oil bath at high temperatures, dropping from 300℃ to 100℃ in just 30 minutes, greatly improving work efficiency.
Equipped with a detachable smoke exhaust to exhaust the oil fumes generated during high temperatures to the outdoors.
The working liquid level remains constant, and the adaptive medium expands at high temperatures without overflow, so there is no need to replenish oil during use.
Adopting jet mixing technology and precise PID temperature control, it can achieve rate temperature control.
Independent overtemperature protection system ensures safe and reliable machine operation.
The instrument feet are designed with adjustable universal wheels, allowing one person to easily move the device.
Small size, light weight, and low noise.

Display range:  0℃∼310℃
Working temperature:  80℃∼300℃
Working medium:  Silicone oil (50cst)
Working area:  Diam 138mm
                        Depth 510mm
Liquid volume:  About 15L
Stirring mode:  Ejector mixing, 3 speeds
Cooling mode:  Forced air cooling
Heating modes:  By electric heater
Temp. control mode:  Full digital PID control
Display resolution:  0.001℃
Stability:  0.01℃/10mins
Display accuracy:  ±0.05℃ (After calibration)
Horizontal temp. field:  0.01℃ (at 100℃)
Vertical temp. field:  0.02℃ (at 100℃)
Heating up time:  About 1hr (30℃∼300℃)
Cooling time:  About 1hr (300℃∼60℃)
Working voltage:  220V±10%, 50Hz
Nominal power:  About 2900W
Size:  About 405x350x870mm
Weight:  About 35Kg

Warranty period of 12 months, free warranty or replacement in case of quality defects

Free information exchange platform technical support, operational answers or video tips, paid maintenance services

Use green refrigerant, compliance with world environmental protection agreement.

Options:

Related product recommendation

产品中心
Intelligent temperature sensor verification and calibration system
Intelligent temperature sensor verification and calibration system
The system adopts multiple innovative technological achievements, and its software and hardware comply with the national temperature calibration regulations. It is independently developed by AIKOM company and has fully independent intellectual property rights, making the maintenance and upgrading of the system easier. The system has the characteristics of advanced design, reasonable structure, complete software functions, convenient operation, strong anti-interference ability, and flexible configuration. It can make the time-consuming and laborious temperature calibration work easy and effortless.
Aneroid barometer visual calibration system
Aneroid barometer visual calibration system
The automatic visual recognition verification system for empty box barometers is developed by AIKOM company specifically for verifying empty box barometers. An automatic control and calibration system composed of hardware units such as computers, atmospheric pressure/temperature calibration devices, visual automatic recognition devices, automatic position finding control devices, automatic lighting assistance devices, and professional software, as well as the calibration and calibration of atmospheric pressure gauges. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "JJG 272-2007 Aneroid Barometer & Aneroid Barograph", achieving functions such as automatic temperature control, automatic pressure rise and fall, automatic pressure control, automatic verification/calibration, automatic photo storage, automatic calculation results, and automatic printing reports.
Calibration system for top-oil/winding temp. measuring equipment of oil transform
Calibration system for top-oil/winding temp. measuring equipment of oil transform
The calibration system for the oil level/winding temperature controller of the main transformer is specially developed by AIKOM company for the temperature measurement device of power transformers. It consists of hardware units such as a computer, a constant temperature bath, a standard thermometer, and a secondary electrical measuring device, as well as professional software. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "DL/T 1400-2015 Calibration specification for local temperature measuringequipment of oil transformer". The entire calibration process only requires the inspector to manually input the temperature bulb wiring and temperature controller readings, while the rest is completed by a computer, such as automatic temperature control, calibration, data processing, calculation, printing reports, and other functions.
Calibration system for measurement and test norm of Thermostatic bath
Calibration system for measurement and test norm of Thermostatic bath's metrological characteristics
The constant temperature bath testing system is designed specifically for testing the technical performance of the constant temperature bath. It is an automatic control and verification software composed of hardware units such as a computer, constant temperature bath, standard platinum resistance thermometer, precision two channel standard platinum resistance thermometer, and professional software. Developed independently by AIKOM, the fluctuation and uniformity of the constant temperature bath are automatically tested in strict accordance with the "JJF 1030-2010 Measurement and Test Norm of Thermostatic Bath Metrological Characteristics". During the entire verification process, only the verifier needs to change the position of the verification point, and the rest are automatically controlled, verified, and processed by the computer. The results are calculated and judged to be qualified, and the test certificate is output
上一页
1
2
17
Online customer service
Customer service hotline
0755-83762498 0755-83762498
Service time:
8:00 - 24:00
Customer service group:
Online Service
QQ:
QQ