Your current position:
Homepage
/
/
/
Integrated desktop data collector
1/1
Number of views:
1107
TA-1210C

Integrated desktop data collector

AIKOM company produces the TA-1210C integrated desktop data collector are high-precision and high stability integrated automatic data measurement and acquisition devices specifically designed for automatic verification systems of thermal resistance and thermocouples. It can also be used for multi-point temperature field distribution collection, data transmission, monitoring and other occasions.
  • Product Description

    AIKOM company produces the TA-1210C integrated desktop data collector are high-precision and high stability integrated automatic data measurement and acquisition devices specifically designed for automatic verification systems of thermal resistance and thermocouples. It can also be used for multi-point temperature field distribution collection, data transmission, monitoring and other occasions.

  • Application areas

    Suitable for direct reading measurement and temperature value display of standard platinum resistance thermometers, standard thermocouples, industrial platinum resistance thermometers, and working thermocouples, as well as high-precision/fast measurement of multi-channel temperature field (temp. difference). It is a secondary standard electrical measuring instrument equipped in temperature laboratories and temperature measurement rooms

  • Product characteristics

    ●Integrated design, integrating 8-digit meter measurement, low thermal potential input terminal acquisition card, temp. value direct reading, and data communication port transmission, facilitating user integration.
    ●11 channel data collection, dual channel simultaneous display facilit-ates data comparison between 2 x 5 ten channels.
    ●It can achieve offline manual operation to complete the measurement value conversion, calculation, data display, etc. required by the regulations, and can be used independently without the control of upper computer software.
    ●Adopting zero temperature drift compensation function and built-in constant temp. device to reduce the impact of environmental temperature changes.
    ●Equipped with constant current source commutation function, which minimizes the impact of measuring thermoelectric potential.
    ●Equipped with the measurement and control function of thermal resistance in three or four wire system, supporting the simultaneous calibration of industrial platinum resistors in three or four wire systems.
    ●Small and portable design with only 260 × one hundred and sixty × The 190mm volume is convenient for outdoor and on-site use.
    ●Support wireless communication port function(Optional)

  • Specificatiom

    Resistance measurement range:  SPRTs: 5Ω~100Ω
                                                         PT100/PT1000:  5Ω~400Ω (PT-100)
                                                                                  40Ω~4000Ω (PT-1000)
    Thermocouple measurement range:  Standard thermocouple: -30~30 mV
                                                                Industrial thermocouple: -100~100mV, -30~30mV
    Temperature transmitter range:  4~20mA
    Temperature display range:  SPRTs: -38.834~29.765℃ (Hg/Ga)
                                                             -189~660.323℃ (Ar/Al)
                                                  PT100/PT1000: -200~850℃ (PT-100, PT-1000)
                                                                         -50~150℃ (Copper resistance)
                                                  Standard thermocouple: -50~1768℃ (Standard S/R type)
                                                  Precious metal dolls for work: -50~1768℃ (S/R type)
                                                                                                 250~1820℃ (B type)
                                                  Low cost metal dolls for work: K/J/N/E/T type
    Thermal resistance measurement mode:  2/3/4 line measure
    Display resolution:  0.00001Ω/0.00001mV/0.0001mA
    Stability:  ±0.001℃/±0.0003mV/±0.0003mA
    Measurement accuracy:  5~100Ω: ±(0.0015%R + 0.0005%FS)
                                            ±30mV: ±(0.003%R + 0.001%FS)
                                            5~400Ω: ±(0.005%R + 0.001%FS)
                                            ±100mV: ±(0.005%R + 0.002%FS)
                                            4~20mA: ±(0.01%R + 0.005%FS)
    Refresh cycle:  0.2Hz
    Constant current:  1.0mA (Alternating)
    Heated stabilization time:  30min
    Connection terminal EMF time:  15seconds
    Connection termina EMF:  ≤0.4μV
    Communication mode:  USB/RS-232or wireless communication (option)
    Working voltage:  220VAC±10%, 50Hz
    Nominal power:  About 30W
    Size:  About 260×190×130mm
    Weight:  About 5.7Kg  

  • Product Warranty

    Warranty period of 12 months, free warranty or replacement in case of quality defects

  • After-sale service

    Free information exchange platform technical support, operational answers or video tips, paid maintenance services

  • Environmental impact

    Comply with environmental requirements

  • optional accessories

    Options:

    ​​​​​​​​​​​​​

Product Description
Application areas
Product characteristics
Specificatiom
Product Warranty
After-sale service
Environmental impact
optional accessories

AIKOM company produces the TA-1210C integrated desktop data collector are high-precision and high stability integrated automatic data measurement and acquisition devices specifically designed for automatic verification systems of thermal resistance and thermocouples. It can also be used for multi-point temperature field distribution collection, data transmission, monitoring and other occasions.

Suitable for direct reading measurement and temperature value display of standard platinum resistance thermometers, standard thermocouples, industrial platinum resistance thermometers, and working thermocouples, as well as high-precision/fast measurement of multi-channel temperature field (temp. difference). It is a secondary standard electrical measuring instrument equipped in temperature laboratories and temperature measurement rooms

●Integrated design, integrating 8-digit meter measurement, low thermal potential input terminal acquisition card, temp. value direct reading, and data communication port transmission, facilitating user integration.
●11 channel data collection, dual channel simultaneous display facilit-ates data comparison between 2 x 5 ten channels.
●It can achieve offline manual operation to complete the measurement value conversion, calculation, data display, etc. required by the regulations, and can be used independently without the control of upper computer software.
●Adopting zero temperature drift compensation function and built-in constant temp. device to reduce the impact of environmental temperature changes.
●Equipped with constant current source commutation function, which minimizes the impact of measuring thermoelectric potential.
●Equipped with the measurement and control function of thermal resistance in three or four wire system, supporting the simultaneous calibration of industrial platinum resistors in three or four wire systems.
●Small and portable design with only 260 × one hundred and sixty × The 190mm volume is convenient for outdoor and on-site use.
●Support wireless communication port function(Optional)

Resistance measurement range:  SPRTs: 5Ω~100Ω
                                                     PT100/PT1000:  5Ω~400Ω (PT-100)
                                                                              40Ω~4000Ω (PT-1000)
Thermocouple measurement range:  Standard thermocouple: -30~30 mV
                                                            Industrial thermocouple: -100~100mV, -30~30mV
Temperature transmitter range:  4~20mA
Temperature display range:  SPRTs: -38.834~29.765℃ (Hg/Ga)
                                                         -189~660.323℃ (Ar/Al)
                                              PT100/PT1000: -200~850℃ (PT-100, PT-1000)
                                                                     -50~150℃ (Copper resistance)
                                              Standard thermocouple: -50~1768℃ (Standard S/R type)
                                              Precious metal dolls for work: -50~1768℃ (S/R type)
                                                                                             250~1820℃ (B type)
                                              Low cost metal dolls for work: K/J/N/E/T type
Thermal resistance measurement mode:  2/3/4 line measure
Display resolution:  0.00001Ω/0.00001mV/0.0001mA
Stability:  ±0.001℃/±0.0003mV/±0.0003mA
Measurement accuracy:  5~100Ω: ±(0.0015%R + 0.0005%FS)
                                        ±30mV: ±(0.003%R + 0.001%FS)
                                        5~400Ω: ±(0.005%R + 0.001%FS)
                                        ±100mV: ±(0.005%R + 0.002%FS)
                                        4~20mA: ±(0.01%R + 0.005%FS)
Refresh cycle:  0.2Hz
Constant current:  1.0mA (Alternating)
Heated stabilization time:  30min
Connection terminal EMF time:  15seconds
Connection termina EMF:  ≤0.4μV
Communication mode:  USB/RS-232or wireless communication (option)
Working voltage:  220VAC±10%, 50Hz
Nominal power:  About 30W
Size:  About 260×190×130mm
Weight:  About 5.7Kg  

Warranty period of 12 months, free warranty or replacement in case of quality defects

Free information exchange platform technical support, operational answers or video tips, paid maintenance services

Comply with environmental requirements

Options:

​​​​​​​​​​​​​

Related product recommendation

产品中心
Intelligent temperature sensor verification and calibration system
Intelligent temperature sensor verification and calibration system
The system adopts multiple innovative technological achievements, and its software and hardware comply with the national temperature calibration regulations. It is independently developed by AIKOM company and has fully independent intellectual property rights, making the maintenance and upgrading of the system easier. The system has the characteristics of advanced design, reasonable structure, complete software functions, convenient operation, strong anti-interference ability, and flexible configuration. It can make the time-consuming and laborious temperature calibration work easy and effortless.
Aneroid barometer visual calibration system
Aneroid barometer visual calibration system
The automatic visual recognition verification system for empty box barometers is developed by AIKOM company specifically for verifying empty box barometers. An automatic control and calibration system composed of hardware units such as computers, atmospheric pressure/temperature calibration devices, visual automatic recognition devices, automatic position finding control devices, automatic lighting assistance devices, and professional software, as well as the calibration and calibration of atmospheric pressure gauges. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "JJG 272-2007 Aneroid Barometer & Aneroid Barograph", achieving functions such as automatic temperature control, automatic pressure rise and fall, automatic pressure control, automatic verification/calibration, automatic photo storage, automatic calculation results, and automatic printing reports.
Calibration system for top-oil/winding temp. measuring equipment of oil transform
Calibration system for top-oil/winding temp. measuring equipment of oil transform
The calibration system for the oil level/winding temperature controller of the main transformer is specially developed by AIKOM company for the temperature measurement device of power transformers. It consists of hardware units such as a computer, a constant temperature bath, a standard thermometer, and a secondary electrical measuring device, as well as professional software. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "DL/T 1400-2015 Calibration specification for local temperature measuringequipment of oil transformer". The entire calibration process only requires the inspector to manually input the temperature bulb wiring and temperature controller readings, while the rest is completed by a computer, such as automatic temperature control, calibration, data processing, calculation, printing reports, and other functions.
Calibration system for measurement and test norm of Thermostatic bath
Calibration system for measurement and test norm of Thermostatic bath's metrological characteristics
The constant temperature bath testing system is designed specifically for testing the technical performance of the constant temperature bath. It is an automatic control and verification software composed of hardware units such as a computer, constant temperature bath, standard platinum resistance thermometer, precision two channel standard platinum resistance thermometer, and professional software. Developed independently by AIKOM, the fluctuation and uniformity of the constant temperature bath are automatically tested in strict accordance with the "JJF 1030-2010 Measurement and Test Norm of Thermostatic Bath Metrological Characteristics". During the entire verification process, only the verifier needs to change the position of the verification point, and the rest are automatically controlled, verified, and processed by the computer. The results are calculated and judged to be qualified, and the test certificate is output