PD-3000A

Freezing point bath

The PD-3000A freezing point bath designed and produced by AIKOM company meets the following regulatory requirements: "JJG 75-2022 Standard Platinum Rhodium 10 Platinum Thermocouple Verification Regulations", "JJG 668-1997 Working Platinum Rhodium 10 Platinum (Platinum Rhodium 13 Platinum) Short Type Thermocouple Verification Regulations" JJG141-2013 Working Precision Metal Thermocouple Verification Regulations, JJG 351-1996 Verification Regulation of Working Base Metal Thermocouple, JJF 1637-2017 Working Low Metal Thermocouple Calibration Regulations, and JJF 1262-2010 Armored Thermocouple Calibration Specification.
  • Product Description

    The PD-3000A freezing point bath designed and produced by AIKOM company meets the following regulatory requirements: "JJG 75-2022 Standard Platinum Rhodium 10 Platinum Thermocouple Verification Regulations", "JJG 668-1997 Working Platinum Rhodium 10 Platinum (Platinum Rhodium 13 Platinum) Short Type Thermocouple Verification Regulations" JJG141-2013 Working Precision Metal Thermocouple Verification Regulations, JJG 351-1996 Verification Regulation of Working Base Metal Thermocouple, JJF 1637-2017 Working Low Metal Thermocouple Calibration Regulations, and JJF 1262-2010 Armored Thermocouple Calibration Specification.

  • Application areas

    Suitable for thermocouple verification /calibration reference cold junction compensation. Within its temperature control range, it can be used as a calibration slot for armored thermocouples with a diameter of 6mm or 1/4 inch, and industrial platinum resistors.

  • Product characteristics

    ●Excellent performance in technical indicators such as tank temperature fluctuation, temperature field uniformity, temperature control accuracy, temperature drift, stability, vibration/noise, etc.
    ●Having an immersion depth of over 200mm, equipped with a 7.5mm glass protective tube for 11 holes.
    ●Using semiconductor cooling, reducing from 25℃ to 0℃ for about 12 minutes.
    ●It can be filled with antifreeze as a whole and is equipped with a water sealed anti overflow cover.
    ●The overall temperature fluctuation is small, the temperature control accuracy is high, and the operation is simple and convenient.
    ●Semiconductor refrigeration, continuous operation, no pollution source, energy-saving and environmentally friendly.
    ●Equipped with power cord, 11 glass tubes, and instrument box.

  • Specificatiom

    Display range:  -5℃~105℃
    Working temperature:  0℃
    Working medium:  Alcohol, Antifreeze
    Liquid volume:  About 120mL
    Number of working holes:  11 holes
    Hole diameter and depth:  Φ7.5x200mm
    Stability:  ±0.005℃/10min
    Display resolution:  0.001℃
    Display accuracy:  ±0.01℃ (0℃)
    Temp. difference between holes:  0.02℃
    Cooling time:  About 12mins (Ambient 25℃~0℃)
    stability time:  About 5min
    Cooling mode:  Semiconductor refrigeration
    Bath structure:  The groove body cannot be replaced with a sleeve
                              Fluid filling between pores helps with heat conduction
    Working voltage:  220VAC±10%, 50Hz
    Nominal power:  About 120W
    Size:  About 170x230x350mm
    Weight:  About 15Kg

  • Product Warranty

    The warranty period is 12 months. In case of quality defects, the warranty or replacement is free of charge

  • After-sale service

    Free information exchange platform technical support, operation answers or video prompts, paid maintenance services

  • Environmental impact

    Semiconductor refrigeration, in line with the world environmental protection agreement

  • optional accessories

    A

Product Description
Application areas
Product characteristics
Specificatiom
Product Warranty
After-sale service
Environmental impact
optional accessories

The PD-3000A freezing point bath designed and produced by AIKOM company meets the following regulatory requirements: "JJG 75-2022 Standard Platinum Rhodium 10 Platinum Thermocouple Verification Regulations", "JJG 668-1997 Working Platinum Rhodium 10 Platinum (Platinum Rhodium 13 Platinum) Short Type Thermocouple Verification Regulations" JJG141-2013 Working Precision Metal Thermocouple Verification Regulations, JJG 351-1996 Verification Regulation of Working Base Metal Thermocouple, JJF 1637-2017 Working Low Metal Thermocouple Calibration Regulations, and JJF 1262-2010 Armored Thermocouple Calibration Specification.

Suitable for thermocouple verification /calibration reference cold junction compensation. Within its temperature control range, it can be used as a calibration slot for armored thermocouples with a diameter of 6mm or 1/4 inch, and industrial platinum resistors.

●Excellent performance in technical indicators such as tank temperature fluctuation, temperature field uniformity, temperature control accuracy, temperature drift, stability, vibration/noise, etc.
●Having an immersion depth of over 200mm, equipped with a 7.5mm glass protective tube for 11 holes.
●Using semiconductor cooling, reducing from 25℃ to 0℃ for about 12 minutes.
●It can be filled with antifreeze as a whole and is equipped with a water sealed anti overflow cover.
●The overall temperature fluctuation is small, the temperature control accuracy is high, and the operation is simple and convenient.
●Semiconductor refrigeration, continuous operation, no pollution source, energy-saving and environmentally friendly.
●Equipped with power cord, 11 glass tubes, and instrument box.

Display range:  -5℃~105℃
Working temperature:  0℃
Working medium:  Alcohol, Antifreeze
Liquid volume:  About 120mL
Number of working holes:  11 holes
Hole diameter and depth:  Φ7.5x200mm
Stability:  ±0.005℃/10min
Display resolution:  0.001℃
Display accuracy:  ±0.01℃ (0℃)
Temp. difference between holes:  0.02℃
Cooling time:  About 12mins (Ambient 25℃~0℃)
stability time:  About 5min
Cooling mode:  Semiconductor refrigeration
Bath structure:  The groove body cannot be replaced with a sleeve
                          Fluid filling between pores helps with heat conduction
Working voltage:  220VAC±10%, 50Hz
Nominal power:  About 120W
Size:  About 170x230x350mm
Weight:  About 15Kg

The warranty period is 12 months. In case of quality defects, the warranty or replacement is free of charge

Free information exchange platform technical support, operation answers or video prompts, paid maintenance services

Semiconductor refrigeration, in line with the world environmental protection agreement

A

Related product recommendation

产品中心
Intelligent temperature sensor verification and calibration system
Intelligent temperature sensor verification and calibration system
The system adopts multiple innovative technological achievements, and its software and hardware comply with the national temperature calibration regulations. It is independently developed by AIKOM company and has fully independent intellectual property rights, making the maintenance and upgrading of the system easier. The system has the characteristics of advanced design, reasonable structure, complete software functions, convenient operation, strong anti-interference ability, and flexible configuration. It can make the time-consuming and laborious temperature calibration work easy and effortless.
Aneroid barometer visual calibration system
Aneroid barometer visual calibration system
The automatic visual recognition verification system for empty box barometers is developed by AIKOM company specifically for verifying empty box barometers. An automatic control and calibration system composed of hardware units such as computers, atmospheric pressure/temperature calibration devices, visual automatic recognition devices, automatic position finding control devices, automatic lighting assistance devices, and professional software, as well as the calibration and calibration of atmospheric pressure gauges. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "JJG 272-2007 Aneroid Barometer & Aneroid Barograph", achieving functions such as automatic temperature control, automatic pressure rise and fall, automatic pressure control, automatic verification/calibration, automatic photo storage, automatic calculation results, and automatic printing reports.
Calibration system for top-oil/winding temp. measuring equipment of oil transform
Calibration system for top-oil/winding temp. measuring equipment of oil transform
The calibration system for the oil level/winding temperature controller of the main transformer is specially developed by AIKOM company for the temperature measurement device of power transformers. It consists of hardware units such as a computer, a constant temperature bath, a standard thermometer, and a secondary electrical measuring device, as well as professional software. Developed independently by AIKOM company and possessing independent intellectual property rights, it is applicable to the "DL/T 1400-2015 Calibration specification for local temperature measuringequipment of oil transformer". The entire calibration process only requires the inspector to manually input the temperature bulb wiring and temperature controller readings, while the rest is completed by a computer, such as automatic temperature control, calibration, data processing, calculation, printing reports, and other functions.
Calibration system for measurement and test norm of Thermostatic bath
Calibration system for measurement and test norm of Thermostatic bath's metrological characteristics
The constant temperature bath testing system is designed specifically for testing the technical performance of the constant temperature bath. It is an automatic control and verification software composed of hardware units such as a computer, constant temperature bath, standard platinum resistance thermometer, precision two channel standard platinum resistance thermometer, and professional software. Developed independently by AIKOM, the fluctuation and uniformity of the constant temperature bath are automatically tested in strict accordance with the "JJF 1030-2010 Measurement and Test Norm of Thermostatic Bath Metrological Characteristics". During the entire verification process, only the verifier needs to change the position of the verification point, and the rest are automatically controlled, verified, and processed by the computer. The results are calculated and judged to be qualified, and the test certificate is output